Product
Specification
|
Description
|
|
DO Range
|
Galvanic: 0.00 – 25.00 mg/l or
0.00 – 300% Saturation
Amperometric: 0.00 – 20.00 mg/l or 0.00 – 200%
Saturation
|
|
Resolution
|
0.01 mg/l or ppm or 0.1 %
|
|
Accuracy
|
Galvanic: ±1.5 % full scale
Amperometric: ± 1% full scale
|
|
Temperature Range
|
-10.0 to 125 °C (14.0 to 257.0
°F)
|
|
Resolution & Relative Accuracy
|
0.1 °C / °F &
±0.5 °C / ±1.0 °F
|
|
Temperature Sensor
|
Galvanic: Pt100/ Pt1000 (jumper
selectable); 2 or 3 wire
Amperometric: NTC 22 kΩ Thermistor
|
|
Temperature Compensation
|
Auto / Manual
|
|
Salinity Compensation
|
0.0 to 50.00 ppt (Manual setting
and Automatic correction)
|
|
Pressure Compensation
|
0.740 to 3.000 Bar; 555 to 2250
mmHg; 10.73 to 43.51 PSI
(Manual setting and Automatic correction)
|
|
Set Point
and Controller Functions
|
|
Integral Time
|
0 to 999.9 minutes
|
|
Switching Hysteresis
|
Galvanic: 0 to 10% full scale
Amperometric: 0.1 to 1.0 mg/l or 1.0 to 10.00
%
|
|
Function (Switchable)
|
P/PI control (Pulse Length / Pulse
Frequency);
Limit Control; Off
|
|
Adjustable Period with Pulse Length
Controller
|
0.5 to 20 seconds
|
|
Adjustable Period with Pulse Frequency
Controller
|
60 to 120 pulses/min
|
|
Pickup / Dropout Delay
|
0 to 2000 seconds
|
|
Wash Cycle
|
0.1 to 200.0 hours
|
|
Wash Duration
|
1 to 2000 seconds
|
|
Contact Outputs, controller
|
1 SPDT, 3 SPST relays
|
|
Switching Voltage / Current /
Power
|
Max 250 VAC / Max 3A / Max 600VA
|
|
Alarm
Functions
|
|
Function (Switchable)
|
Latching / pulse
|
|
Pickup Delay
|
0 to 2000 seconds
|
|
Display
|
|
LCD
|
UV coat, backlit 14 segments display
with symbols for status information
|
|
Backlight
|
On/Off selectable with four levels
of brightness control
|
|
Electromagnetic
Compliance (EMC) Specifications
|
|
Emitted Interference
|
According to EN 61326
|
|
Immunity to Interference
|
According to EN 61326
|
|
Environmental
Conditions
|
|
Ambient Temperature Operating
Range
|
0 to 50 °C
|
|
Maximum Relative Humidity
|
80% up to 31 °C decreasing linearly
to 50%
at 40 °C
|
|
Power Supply
|
|
Input
|
80 to 250 VAC/DC 50/60 Hz Approx.
10 VA
|
|
Main Fuse
|
Galvanic: 315 mA Anti-surge, 250
V
Amperometric: 250 mA, Anti-surge
|
|
Pollution Degree
|
2
|
|
Transient Overvoltage Category
|
II
|
|
Electrical
Data and Connections
|
|
Transmitter Function
|
Two 0/4 to 20 mA scalable outputs
for pH/ORP and temperature, galvanically isolated
|
|
Load
|
Max 600 W
|
|
DO Input
|
Screw terminals
|
|
Connection Terminal
(Galvanic)
|
5-pin, 8-pin, 9-pin and 13-pin
terminal, detachable blocks
|
|
Connection Terminal
(Amperometric)
|
Wall mount: 2x3-pin, 8-pin 9-pin
and 13-pin terminal blocks
Panel mount: 3-pin, 9-pin and 19-pin terminal
blocks
|
|
Mechanical
Specifications
|
|
Dimensions (W x H x D)
|
Wall-mount (Galvanic)
Wall-mount (Amperometric)
Panel-mount
|
144 x 144 x 111.5 mm
144 x 144 x 110 mm
175 x 96 X 96 mm
|
|
Weight
|
Wall-mount
Panel-mount
|
745g (Unit) / 1100g (Packed)
700g (Unit) / 850g (Packed)
|
|
Environmental Rating
|
Wall-mount
Panel-mount
|
IP66 (NEMA 4X)
IP54 (front panel)
|